Anti-Islanding detection methods: Frequency, voltage and utility impedance.
Build-in MPPT (Maximum Power Point Tracking) function.
High efficiency with wide range operation.
Design to meet VDE0126-1-1 requirements.
Easy assembly in production line.
Easy replacement when servicing. The mean time of service is less than
20 minutes.
Firmware flash capability: The firmware inside the micro-controllers can be updated by optional communication interface.
GFCI: Ground Fault Current Interruption, which is also known as RCD (Residual Current Device). To prevent electrical hazard of user, a current transformer monitoring the difference between L and N current is applied. When the current difference is larger than specified value stated in section ¡§General Data¡¨, inverter will cut its output to grid.
Bundled software for user buying optional communication card.
Model
SLK-1500
SLK-2000
SLK-3000
SLK-4000
SLK-6000
Input Data
Maximum Input Power
1750W
2340W
3510W
4700W
6500W
Nominal DC voltage
360V~400V
Max. input voltage
Maximum PV open voltage
500VDC
600VDC
MPPT voltage range
150V to 500V +/-5%
150V to 600V +/-5%
System start-up voltage
100 +/-5%
Working voltage range *
100 +/-5% ~ 500-5%+0%V
100 +/-5% ~ 600-5%+0%V
Initial feeding voltage *
150V +/-5%
Full rating working range
200V to 500V
250V to 500V
250V to 600V
Max. input current
7.5ADC
10ADC
15.2ADC
20ADC
30ADC
Shutdown voltage
80V typical
DC voltage ripple
< 10%
DC insulation resistance **
> 8M ohm
DC Switch
On/Off 20A
On/Off 30A
DC Connector
Tyco or MC contract (1-pair) - cable type
Tyco or MC contact (3 pairs)
Attachd DC Connector
Tyco-contact (1 pair)
Output data
Nominal output power
1500W
2000W
3000W
4000W
6000W
Maximum output power
(The time is limited to 10 minutes @ 50°C ambient)
1650W
2200W
3300W
4400W
6000W
Operational Voltage range ***
198V, minimum
256V maximum
Operational Normal voltage
230 Vac
Operational frequency range
50/60Hz, auto selection
47.5<f50<50.2 for 50Hz
59.3<f60<60.5 for 60Hz
Nominal output current
6.6A
8.7A
13.1A
17.4A
26.1A
O/P current distortion
THD<5%, each harmonics <3%
Power Factor
> 0.99%
DC current injection
<0.5% of rated inverter output current
General Data
Internal power consumption
< 7W
Standby power (at night)
< 0.1W
Minimum conversion efficiency (DC/AC)
>90%
Under input voltage>210V, load >20%
Maximum Conversion Efficiency (DC/AC)
>94%
>95%
>95%
>96%
European Efficiency
>93%
>94%
>94%
>95%
GFCI threshold
See ground fault current detection
Ground current detection range
0~500mA
Ground current detection frequency
0~700Hz
DC input impedance requirement
>2M Omega
Protection degree
IP 65 or IP43
Operation temperature
-25 to 55°C
Humidity
0 to 95%, non-condensing
Heat Dissipation
Convection
Acoustic noise level
<40dB, A-weighted, frequency up to 20kHz
Altitude
Up to 3000m without power derating, 5°C derated for each additional 500m
* Load curve :
The relation of input DC voltage and output power is shown in figure. Once input V is less than 250V, the relation of I/P V and load % is : Load% = 0.4 x Vi
1. This is voltage range that inverter will start to feed power to grid.
2. The DC resistance requirement for positive or negative terminal to chasis ground
3. In VDE0126-1-1, it is ¡V20%/ +15%. DK5940, RD1663 are also available.
4. Based on the limit of VDE0126-1-1
5. Based on limit of IEEE929
6. Under the output voltage is 230VAC
7. Under utility voltage THD<3%
8. under input voltage>= 400V, full rated output power, 25oC ambient
9. According to VDE0126-1-1 requirement
Mechanical Requirements:
Model
SLK-1500
SLK-2000
SLK-3000
SLK-4000
SLK-6000
Physical: W*D*H (mm)
352*300*133
352*300*133
352*300*133
550*300*133
550*420*143
Physical: Weight (kg)
14
14
14
21
24
Shipping: W*D*H (mm)
460*460*265
460*460*265
460*460*265
660*460*265
660*580*265
Shipping: Weight (kg)
16
16
16
23
26
** The dimension and weight here could be changed due to product modification